PRODUCT FINDER

Horizontal Lifeline Systems

HORIZONTAL LIFELINE SYSTEM ON TRAPEZOIDAL COLD ROOF PLATES

Lifeline system on connector on XTrusion base plate

XTRUSION WITH CONNECTOR

A horizontal lifeline system (HLL), such as the XSLinked system, is designed to keep workers safe, while moving around at height. Depending on the system type and the installation method the system can be used by 1 to 2 users at a time.

The lifeline consists of a steel wire-rope trajectory that is spanned between several anchor points. These anchor points are installed to steel trapezoidal cold roof plates, with a minimum thickness of 0,63 mm (24 gauge), by means of the AISI 316 XTrusion base plate. In this case installation occurs with four AISI 316 mounting bases and sixteen pieces of Gesipa 7,7 mm (5/16”) bulb-tite rivets.

Lifeline systems with XSConnector components have no integrated energy absorption. These systems need to be equipped with individual energy absorbers, such as the XSDynamic, when used as a fall arrest system. This will help to protect the roof structure in case a fall occurs.

All XSPlatforms fall protection systems are designed, tested and certified in accordance to the latest European standards EN 795:2012 type A/C and CEN-TS 16415:2013 type C.

You can use our online calculation tool, ODIN, to calculate horizontal lifeline configurations.

SPECIFICATIONS


  • Steel trapezoidal cold roof plates
  • Thickness of 0,63 mm (24 gauge)
  • Installation with Gesipa 7.7 mm (5/16”) bulb-tite rivets
  • Roof pitch of 15 degrees
  • Suitable for 1 to 2 users
  • Suitable for both fall arrest and fall restraint
  • Energy absorption with XSDynamic
  • Durable stainless steel components
  • EN 795:2012 type A/C and CEN-TS 16415:2013 type C

DOWNLOADS


Lifeline system on connector on cold roof structure

XSMD WITH CONNECTOR

A horizontal lifeline system (HLL), such as the XSLinked system, is designed to keep workers safe, while moving around at height. Depending on the system type and the installation method the system can be used by 1 to 2 users at a time.

The lifeline consists of a steel wire-rope trajectory that is spanned between several anchor points. These anchor points are installed to steel trapezoidal cold roof plates, with a minimum thickness of 0,63 mm (24 gauge), by means of the aluminum XSMD base plate. In this case installation occurs with twelve Gesipa 7,7 mm (5/16”) bulb-tite rivets.

Lifeline systems with XSConnector components have no integrated energy absorption. These systems need to be equipped with individual energy absorbers, such as the XSDynamic, when used as a fall arrest system. This will help to protect the roof structure in case a fall occurs

All XSPlatforms fall protection systems are designed, tested and certified in accordance to the latest European standards EN 795:2012 type A/C and CEN-TS 16415:2013 type C.

You can use our online calculation tool, ODIN, to calculate horizontal lifeline configurations.

SPECIFICATIONS


  • Steel trapezoidal cold roof plates
  • Thickness of 0,63 mm (24 gauge)
  • Installation with Gesipa 7.7 mm (5/16”) bulb-tite rivets
  • Roof pitch of 15 degrees
  • Suitable for 1 to 2 users
  • Suitable for both fall arrest and fall restraint
  • Energy absorption with XSDynamic
  • Durable stainless steel components
  • EN 795:2012 type A/C and CEN-TS 16415:2013 type C

DOWNLOADS


Horizontal lifeline on XTrusion base plate

XTRUSION WITH BENDING KIT

A horizontal lifeline system (HLL), such as the XSLinked system, is designed to keep workers safe, while moving around at height. Depending on the system type and the installation method the system can be used by 1 to 2 users at a time.

The lifeline consists of a steel wire-rope trajectory that is spanned between several anchor points. These anchor points are installed to steel trapezoidal cold roof plates, with a minimum thickness of 0,63 mm (24 gauge), by means of the AISI 316 XTrusion base plate. In this case installation occurs with four AISI 316 mounting bases and sixteen Gesipa 7,7 mm (5/16”) bulb-tite rivets.

Lifeline systems with XSBending kits have integrated energy absorption, due to the patented bending kit system, this will help to protect the roof structure in case a fall occurs.

All XSPlatforms fall protection systems are designed, tested and certified in accordance to the latest European standards EN 795:2012 type A/C and CEN-TS 16415:2013 type C.

You can use our online calculation tool, ODIN, to calculate horizontal lifeline configurations.

SPECIFICATIONS


  • Steel trapezoidal cold roof plates
  • Thickness of 0,63 mm (24 gauge)
  • Installation with Gesipa 7.7 mm (5/16”) bulb-tite rivets
  • Roof pitch of 15 degrees
  • Suitable for 1 to 2 users
  • Suitable for both fall arrest and fall restraint
  • Integrated energy absorption
  • Durable stainless steel components
  • EN 795:2012 type A/C and CEN-TS 16415:2013 type C

DOWNLOADS


Horizontal lifeline on cold roof structure

XSMD WITH BENDING KIT

A horizontal lifeline system (HLL), such as the XSLinked system, is designed to keep workers safe, while moving around at height. Depending on the system type and the installation method the system can be used by 1 to 2 users at a time.

The lifeline consists of a steel wire-rope trajectory that is spanned between several anchor points. These anchor points are installed to steel trapezoidal cold roof plates, with a minimum thickness of 0,63 mm (24 gauge), by means of the aluminum XSMD base plate. In this case installation occurs with twelve Gesipa 7,7 mm (5/16”) bulb-tite rivets.

Lifeline systems with XSBending kits have integrated energy absorption, due to the patented bending kit system, this will help to protect the roof structure in case a fall occurs.

All XSPlatforms fall protection systems are designed, tested and certified in accordance to the latest European standards EN 795:2012 type A/C and CEN-TS 16415:2013 type C.

You can use our online calculation tool, ODIN, to calculate horizontal lifeline configurations.

SPECIFICATIONS


  • Steel trapezoidal cold roof plates
  • Thickness of 0,63 mm (24 gauge)
  • Installation with Gesipa 7.7 mm (5/16”) bulb-tite rivets
  • Roof pitch of 15 degrees
  • Suitable for 1-2 users
  • Suitable for both fall arrest and fall restraint
  • Integrated energy absorption
  • Durable stainless steel components
  • EN 795:2012 type A/C and CEN-TS 16415:2013 type C